Opened 12 years ago

Closed 12 years ago

Last modified 10 years ago

#109 closed Bug (fixed)

IControl: should only be connected when no other I/Os are connected

Reported by: Thomas Schmid Owned by: Thomas Schmid
Priority: Important Milestone:
Component: AnotherEditor Keywords:
Cc:

Description

Slave I/Os have to be invisible after connecting Master and connections should only be allowed when no I/Os are connected. (SuperTooltip)

Change History (2)

comment:1 Changed 12 years ago by Thomas Schmid

Resolution: fixed
Status: newclosed

(In [1048]) - fixed #109

  • created new helper class SuperTooltip in CrypPluginBase
  • control connections to slaves that have connected I/Os are not allowed any more (SuperTooltip is shown) => all KeySearcherSamples won't work any more! KeySearcher plugin has to be modified: Data I/Os, that where used from slave plugins before, have to be implemented in KeySearcher plugin
  • after creating control connection to slave plugin, all I/Os of the slave are removed
  • added opacity effect while showing connection adorner is above slave input
  • new binaries

comment:2 Changed 10 years ago by Matthäus Wander

Milestone: CrypTool 2.0 RELEASE
Note: See TracTickets for help on using tickets.